Find Product

Select a Category:

CAT6OUTDOOR-1M OUTDOOR SOLID CAT6 CABLE – 1M WATER BLOCK TAPE (PER METRE)

Approved for outdoor use only; has not been rated for indoor use

Only outdoor testing criteria were used for this cable’s approval. This does not mean that it does not meet indoor cabling requirements, but it has not been approved. Please consider this before purchasing.

Doss’ Outdoor CAT6 cable is suitable for installation outdoors, in buried conduits and roof mounted WISP client installations. The water-blocking tape layer is cleaner than gel-based water-blocking layers, making installation mess and hassle-free!

  • Water-blocking tape rather than messy gel
  • U/UTP, 23 AWG solid bare copper
  • CMX Outdoor; sunlight-resistant
  • Cross-filler retains cable geometry and pair separation

Construction

Conductor Size 23AWG
Construction Solid Bare Copper
Insulation Avg. Thickness 0.193 mm
min Thickness 0.183 mm
Diameter 0.94 ± 0.01 mm
Material HDPE
Colour Codes
  1. Blue x White/Blue Stripe
  2. Orange x White/Orange Stripe
  3. Green x White/Green Stripe
  4. Brown x White/Brown Stripe
Shielding Pair Stranded 2 Cores Stranded
Filler (Slot) PE Isolator Separator
Assembly Stranded 4 Pair Stranded
Shielded Mylar Tape
Shielded Waterblocking Tape
Jacket Avg. Thickness 0.50 mm
min Thickness 0.47 mm
Diameter 6.70 ± 0.20mm
Material PE
Colour Black

Specifications

Rating 75°C 300V
Conductor Resistance 9.38 Ω / 100m (20°C Max)
Mutual Capacitance 56 pF/m max
Dielectric Strength AC 1.5 kV min
Spark Test 2.5 kV
Insulation Unaged Tensile Strength 2400 PSI min (1.69 kg/mm2)
Elongation 300% min
Aged Tensile Strength Unaged min 75% (100°C x 48hrs)
Elongation Unaged min 75% (100°C x 48hrs)
Jacketed Unaged Tensile Strength 1400 PSI min (0.99 kg/mm2)
Elongation 350% min
Aged Tensile Strength Unaged min 75% (100°C x 48hrs)
Elongation Unaged min 75% (100°C x 48hrs)
Insulation Shrinkback 150m/m, 121°C ± 1°C x 1hr = 9.5m/m
Cold Bend Test -20°C x 4hrs No Crack
Flame Retardant / UV Protection Test CMX
AC Leakage Current Through Overall Jacket AC 1500V ≤10mA
DC Resistance Unbalanced 5% max
Pair-to-ground Capacitance Unbalanced 330 pF/100m max
Propagation Delay 600MHz 535.5 nS / 100m max
Delay Skew 1~600MHz 45nS / 100m max

 

Performance

Frequency (MHz) IL max (dB/100m) NEXT min (dB) ACR min (dB) PS. NEXT min (dB) PS. ACR min (dB) ACRF min (dB/100m) PS. ACRF min (dB/100m) R.L. min (dB)
1 2.0 76.3 74.3 74.3 72.3 67.8 64.8 20.0
4 3.8 67.3 63.5 65.3 61.5 55.7 52.7 23.0
8 5.3 62.8 57.5 60.8 55.5 49.7 46.7 24.5
10 6.0 61.3 55.3 59.3 53.3 47.8 44.8 25.0
16 7.6 58.3 50.7 56.3 48.7 43.7 40.7 25.0
20 8.5 56.8 48.3 54.8 46.3 41.7 38.7 25.0
25 9.5 55.3 45.8 53.3 43.8 39.8 36.8 24.3
31.25 10.7 53.9 43.2 51.9 41.2 37.9 34.9 23.6
62.5 15.4 49.4 34.0 47.4 32.0 31.8 28.8 21.5
100 19.8 46.3 26.5 44.3 24.5 27.8 24.8 20.1
155 25.1 43.5 18.4 41.5 16.4 23.9 20.9 18.8
200 29.0 41.8 12.8 39.8 10.8 21.7 18.7 18.0
250 32.8 40.3 7.5 38.3 5.5 19.8 16.8 17.3
300 36.4 39.2 2.8 37.2 0.8 18.2 15.2 16.8
400 43.0 37.3 35.3 15.7 12.7 15.9
550 51.8 35.2 33.2 12.9 9.9 14.9
600 54.5 34.6 32.6 12.2 9.2 14.7